Data centres have been quite misunderstood. Most people think they’re just ‘server boxes’ and while that definition may be true on a very basic level, it’s these ‘boxes’ that drive the modern economy.

Ninety percent of all collective information created in the past decade lives on the Internet. The storage and exchange of information through the web is made possible by data centres. Governments, enterprises, and consumers around the world have a vital dependence on computer systems, software and networks, and data centres to keep their countries, businesses, and everyday lives running.

There is a challenge to this reliance on technology - to keep systems, software and data centres operational requires incredible amounts of energy. This is especially true in a country like Singapore, which has a tropical climate and high humidity levels that contribute to the already-high energy footprints generated by data centres and systems.

Based on Infocomm Development Authority of Singapore’s (“IDA”) estimates, the 10 largest data centre operators in Singapore use the same amount of energy as 130,000 typical Housing and Development Board (“HDB”) households, a figure that is bound to rise as the data centre base continues to grow in the Republic. As such, in a press release announcing the launch of the Green Data Centre Innovation Programme (GDCIP), IDA pointed out that data centre operators need to consider emerging technologies to improve energy efficiency.

At IO, we have identified a way to help our customers reduce their energy footprint by providing technology in our colocation data centres that allows for a Power Usage Effectiveness (“PUE”) level that is lower than our competitors.

Lower PUE – why does it matter?A data centre typically has three key components – energy, water, and information. One component captures and transmits energy to the data centre. The second component is the data centre itself which is responsible for power conditioning, cooling, security and other support systems. And finally, the customer’s IT system that is housed within the data centre is responsible for turning energy into information.


Figure 1. The water-energy-information system

Figure 1. The water-energy-information system

 At IO, we tested a theory that suggested that data centre design could play a part in increasing energy efficiency and saving costs by comparing the energy usage between a modular data centre and a traditional raised floor data centre over a one-year period. To ensure fair comparisons between the two, both data centre environments were tested within the same geography. This meant that the weather conditions faced by the building’s cooling system which housed both environments were identical. The two environments also shared the same chiller plant, which is used to cool the water used in the data centre.

After a year of testing and monitoring, it was found that a customer with 1 megawatt (MW) of IT load will require 1.73MW of facility power in a traditional raised floor environment versus 1.41MW in a modular environment. The difference might seem small but a .32MW savings over the course of 8,760 hours in a year has a direct impact on energy cost, the amount of water used, and overall carbon emission levels.  

The figure below shows the total amount of savings incurred through using a modular design​.

Figure 2. Total cost, carbon emission, and water savings incurred when using a modular data centre design (right-hand column)

The results say ‘Go modular’

The comparative study demonstrated that IO’s modular data centre deployment resulted in 19% energy cost savings and 44% energy waste reduction compared to the traditional raised-floor data centre environment.

In a modular design, each module houses a much smaller volume of air per server than an open floor. Furthermore, high density modules can sit next to low density modules and the cooling system can cater to the requirements of each. IO’s modules are cooled via a bi-directional chilled water loop that runs around the bottom of the units. This approach allows for large amounts of savings just on cooling alone.

With a modular approach, data centre capacity can also be deployed in smaller units and on-demand, just as storage compute and networking are delivered. This eliminates the wasteful over-provisioning of capacity found in traditional environments, thus reducing an organisation’s energy costs and carbon footprint.

From a business standpoint, the modular data centre concept also lowers business risk. Companies don’t have to build entire sites based on an anticipated three to five year forecast. Instead they can build their data centres for the twelve to 18 months and add capacity as needed, as additional units can be added to the modular sites to increase capacity quickly as needs change. This allows organisations to manage their cash flow better and invest in other business segments as needed.

Overall, the case to go modular is strong – your data centre should be an asset that grows and adapts to internal business changes or the greater IT world versus being an underutilised, over-provisioned, and expensive investment.

To find out more about IO’s research between traditional raised floor data centres and modular models, download the whitepaper here

1 SP Services (2016, March). Historical Tariff Table. Retrieved from Energy Market Authority website https://www.ema.gov.sg/Non_Residential_Programmes_Electricity_Tariffs.aspx
2 Energy Market Authority (2016, April). Grid Emission Factor. Retrieved from Energy Market Authority (EMA) website https://www.ema.gov.sg/cmsmedia/Publications_and_Statistics/Statistics/OTS12.pdf
3 P. Flynn, IO. (2015). Quantitative analysis of energy and financial savings for full-year operation of modular data center relative to raised floor environment.

Pitfalls to avoid when configuring cloud firewalls
Flexibility and granularity of security controls is good but can still represent a risk for new cloud adopters that don’t recognise some of the configuration pitfalls.
Cisco dominates record-high Ethernet switch & router markets
While the market is flourishing, it’s tough-going as Cisco has increased its majority share of the pie.
Tensions on the rise after Huawei CFO arrest
“Recently our corporate CFO, Meng Wanzhou, was provisionally detained by the Canadian authorities on behalf of the United States of America."
Why total visibility is the key to zero trust
Over time, the basic zero trust model has evolved and matured into what Forrester calls the Zero Trust eXtended (ZTX) Ecosystem.
Gartner names Proofpoint Leader in enterprise information archiving
The report provides a detailed overview of the enterprise information archiving market and evaluates vendors based on completeness of vision and ability to execute.
QNAP introduces new 10GbE and Thunderbolt 3 NAS series
The new series is supposedly an all-in-one NAS solution for file storage, backup, sharing, synchronisation and centralised management. 
HPE to supply tech to Formula E racing team
“At HPE, we believe the future belongs to the fast, and we’re focused on accelerating what’s next for enterprises, including in the world of auto racing."
Data Exchange Networks achieves world-first
After receiving a new Uptime Institute award, DXN is now the first modular data centre developer in the world equipped to blend different standards.