02 May 2017

With the many advances that we’ve seen with respect to air and water economizers for data center cooling systems (usually called free-cooling chillers in Europe), it’s no exaggeration to say that no matter where your data center is located on the planet, it can take advantage of economizer solutions to reduce cooling costs – in some cases dramatically – along with your carbon footprint.

The graphic below illustrates the point for a chilled water system, based on water economizer with an adiabatic system.

It shows the gains to be had from using newer economizer cooling systems vs. traditional systems, along with employing three techniques: a relatively high supply chilled water temperature, up to 20°C to the data center air conditioners (a topic we covered in a previous post); a greater differential between the chilled water supply and return temperatures, known as the delta T; and an integrated adiabatic system for the heat exchangers.

In particular, the adiabatic system reduces the energy impact both in summer and in mid-season more, operating for the large part of the year.

Let’s take Paris as an example.

In the graphic, we’re comparing a data center in Paris that uses traditional water economizer units and a typical delta T of 6°C (incoming chilled water of 18°C and outgoing at 24°C) with the same data center using a delta T of 10°C (18/28°C) along with a new water economizer solution, known as adiabatic or evaporative cooling.

The combination of the two provides a 22% increase in energy efficiency – a number that means huge dollar savings for a large data center. 

Comparison calculated comparing traditional water economizer units at 18/24°C with water economizers with adiabatic at 18/28°C

Based on the chart, savings can be realized anywhere on the globe, even in temperate climates such as New Delhi or Buenos Aires.

What’s interesting is you can also get savings in colder climates like Moscow, even though data centers in such areas already benefit greatly from traditional economizer systems that rely on cold air.

Why is this?

Adiabatic systems leverage water evaporation to reduce the temperature of the air, thus improving unit efficiency, regardless if it is an air economizer or a free-cooling chiller.

It’s the same principle that makes you feel chilly when you come out of the water at the beach – as water evaporates, it takes heat away from you.

In water economizers, the adiabatic process involves use of nozzles positioned over air economizer coils that essentially shrouds them in a fine mist, like a fog.

As the mist evaporates, it takes heat with it, cooling the refrigerant and the water inside the coils. (Speaking of which, changes are coming in the refrigerants we use in data center cooling systems, as I discussed in this previous post).

In air economizers, the evaporative process is based on keeping the air-to-air heat exchanger wet, maximizing the natural thermal exchange between the air from the data center and the outdoor air without mixing.

An embedded control system monitors and controls the operation. In short, it only uses water when needed for additional cooling and can also use auxiliary trim cooling when necessary, to deal with high temperatures or humidity.

By taking advantage of variable speed drive technology that optimizes cooling capacity to exact requirements at any given time, companies can save even more on data center cooling costs.

Large and hyperscale data center owners are always looking for a way to save even a single percentage point in energy consumption, because it translates into millions of dollars over the years.

They’re also rightfully concerned about lowering their carbon footprint, which relates not just to electricity, but water consumption, to optimize the total cost of ownership.

Just considering energy usage, it is possible to use the pPUE (partial Power Usage Effectiveness), a well know parameter to identify and compare the efficiency levels of different technologies.

The diagram below makes clear how the more an innovative approach is used in data center design, choosing the latest technologies, the lower the pPUE can be, resulting in a huge impact on data center efficiency.

Adiabatic cooling systems such as Schneider Electric’s EcoflairTM fit the bill on both fronts, by reducing both energy and water consumption.  

Article by Maurizio Frizziero, Schneider Electric Data Center Blog

Story image
Huawei's data center switches receive Frost & Sullivan award
Frost & Sullivan has named Huawei’s CloudEngine 16800 as the recipient of the 2020 Global Data Center Switch Technology Leadership Award.More
Link image
Windows & Linux server monitoring for just $9 a month
Monitor your entire server infrastructure and get in-depth visibility into key performance indicators of your data center's Windows & Linux servers.More
Story image
Server market and ESS revenues slump as COVID-19 spreads - IDC
The enterprise storage systems market as well as server markets will see declines in the first two quarters of 2020, but are expected to recover near the end of the year, according to IDC.More
Story image
IT pros fear threats to critical infrastructure, report shows
IT professionals are concerned about operational technology (OT) security and attacks on critical infrastructure, with a number of people saying the responsibility lies with government, according to a new report.More
Story image
ThousandEyes launches outage map as internet usage explodes during COVID-19 outbreak
"Over the past couple of weeks, we’ve been inundated with requests from businesses, industry analysts and other various parties wanting to get a better understanding of global internet health during these trying times."More
Story image
Nutanix & Udacity launch hybrid cloud nanodegree program
Nutanix is sponsoring 5000 scholarships, to be taught via Udacity, which will school IT professionals on topics such as modern private cloud infrastructure and the design of hybrid application deployment.More